IRD8800 (8800), M88500 (88500) - Differential Expansion Module, 2Ch Eddy current pickup input, API Standard 670 Compliant, Input: 24 V DC
The M88500 monitors turbine differential expansion from two non-contact eddy current sensors (A and B), in complementary or ramp mode. It provides a 4-20 mA output proportional to full scale, alarm and trip relays for the differential expansion result, and RS-485 Modbus RTU (Modbus TCP available on request); standard full scale is ±6.00 mm to ±13.00 mm depending on sensor sensitivity. Spare card for the IRD8800 online monitoring system.

M88500 – Differential Expansion Module (IRD8800 Series)
The M88500 is the differential expansion module of IRD8800 turbine supervisory instrumentation. It takes two non-contact eddy current sensors and computes complementary or ramp differential expansion, with ramp-angle compensation.
Key features
- 2 eddy current inputs (A and B)
- Complementary and ramp differential expansion
- Supports 1.4, 0.8, 0.63 and 0.4 V/mm sensors
- 4-20 mA proportional to full scale, saturating at 4/20 mA beyond ±max
- Alarm and trip relay for the A/B result
- Start-up protection; RS-485 Modbus RTU (Modbus TCP on request)
- NEAR / ZERO / FAR indication
Specifications
| Parameter | Value |
|---|---|
| Inputs | 2 non-contact eddy current sensors |
| Full scale (standard) | 1.4 V/mm: ±6.00 mm; 0.8 V/mm: ±6.75 mm; 0.63 V/mm: ±12.50 mm; 0.4 V/mm: ±13.00 mm. Other full scales selectable |
| 4-20 mA | Proportional to full scale, e.g. ±6 mm → 4–20 mA; backplane terminals 5–6 |
| Relays | Alarm and trip relay for the A/B result |
| Hysteresis | ±2.5 mm (±0.1 in) |
| Modbus | RS-485 Modbus RTU; Modbus TCP also available on request |
| Buffered output | None |
| Power | +24 V DC, 1.25 A (30 VA) |
Documents
Part of the IRD8800 Series API 670 machinery protection system, made in India by IRD Mechanalysis. Online-system warranty: 3 years. More about IRD8800