IRD Mechanalysis Limited
Currency
0

IRD301 Lite - Entry Level Vibration Meter

Simple | Low Cost | Made in India

Jump to Section

The Simple, Low-Cost Vibration Meter for Every Maintenance Team

One button. Reads vibration velocity in mm/s RMS. Complete kit, Made in India by IRD Mechanalysis (founded 1955).

Made in IndiaFounded 19551-Year WarrantyCalibration & repair at our Thane works
IRD301 vibration meter – 2-pin connector for the sensor coiled cable

2 Pin Connector for Connection to Vibration Sensor via Coiled Cable

IRD301 Lite digital vibration meter with 3½-digit LCD and QR code

Easy-to-Read 3 1/2 Digit LCD Display with QR Code for accessing help

IRD301 single-button vibration meter with low-battery LED

Simple - Only 1 Button. Indication Lamp for Low Battery 

What's in the Box?

  • Vibration Meter IRD301 measuring 0–200 mm/s RMS vibration velocity × 1
  • Vibration Sensor – Accelerometer IRD521, 100 mV/g ±10% × 1
  • Coiled cable with 2-pin MS connector at sensor end and 2-pin MRS connector at meter end × 1
  • 9" stinger for hard-to-reach spaces × 1
  • 20 kg pull magnetic base with safety plate × 1
  • 9V rechargeable battery × 1
  • Battery charger × 1
  • IRD-branded hard carrying case × 1 (standard)

Optional add-on: soft carry bag (sling type) – buy online.

IRD301 vibration meter kit in hard carry case

IRD301 Specifications

MeasurementVibration velocity, mm/s RMS
Range0–200 mm/s RMS
Frequency range5 Hz to 2500 Hz
Accuracy±10% with sensor
StandardISO 20816
Display3½-digit LCD with QR code for help
ControlsSingle button (power on/off)
SensorIRD521 accelerometer, 100 mV/g ±10%, via coiled cable
Power1 × 9V rechargeable battery (charger included); low-battery LED
Kit weightapprox. 3 kg
Warranty1 year
Kit contentsMeter, IRD521 sensor, 1 coiled cable, 9" stinger, 20 kg magnetic base with safety plate, 9V rechargeable battery, charger, hard carrying case (standard). Soft carry bag optional.

Equipping a whole plant or team?

Ask us for a bulk price on IRD301 kits.

Request a Bulk / Plant-wide QuoteWhatsApp Us

Trusted by Major Companies

Siemens logo
Farhan Heavy Electricals logo

​​Introductory Video on IRD301

▶

IRD301 Vibration Measurement on a Shaker

▶

IRD301 reading on a running motor

▶

Optional soft carry bag – hard case already included

Which IRD vibration meter is right for you?

IRD301 LiteIRD306DP PlusIRD811D Pro
Best forRoutine checks by operatorsGeneral machinery checksVibration + bearing condition
Velocity (mm/s RMS)✔ 0–200✔ up to 200✔
Displacement–✔ up to 2000 µm pk-pk✔
Acceleration––✔
Bearing condition (Spike Energy™)––✔
Warranty1 year1 year1 year
Kit price (excl. taxes)₹32,779₹70,497₹1,08,625
Buy IRD301 KitView IRD306DP PlusView IRD811D Pro

Prices shown are without taxes; the store shows your local currency at checkout.

IRD301 – Frequently Asked Questions

What does the IRD301 measure?

Overall vibration velocity in mm/s RMS, from 0 to 200 mm/s. The 100 mV/g signal from the IRD521 accelerometer is integrated into velocity and shown on the display. On a shaker running at 1.414 g pk and 159.2 Hz (9.8 mm/s RMS), the IRD301 reads 9.8 mm/s RMS.

What are the IRD301's range, frequency range and accuracy?

0–200 mm/s RMS, 5 Hz to 2500 Hz, ±10% with sensor. Readings can be compared against ISO 20816 vibration severity limits.

Which sensor does the IRD301 use?

An IEPE-type accelerometer of 100 mV/g sensitivity. The IRD521 (100 mV/g) is supplied with it in the kit.

What's in the IRD301 kit?

IRD301 meter, IRD521 accelerometer (100 mV/g), 1 coiled cable, 9" stinger, 20 kg magnetic base with safety plate, 9V rechargeable battery, charger and IRD hard carrying case (standard). A soft carry bag is available as an optional add-on.

Which cable comes in the standard kit?

One coiled cable (qty 1) with a 2-pin MS connector at the sensor end and a 2-pin MRS connector at the meter end, 0.8 m collapsed and 3 m extended. Spare cables can be ordered from sales@irdmech.com or bought online.

How do I switch the IRD301 on and off?

It has just one button on the front. Press and release it once to power on, and once again to turn off.

When does the Change Battery LED glow?

When the 9V battery drops to 8.3 V DC or lower. Recharge the battery with the charger in the kit or replace it.

How do I get an accurate reading?

Keep the meter and sensor in calibration (both carry a calibration sticker), use a healthy 9V battery and the correct cable. Mount the IRD521 firmly by hand, stud, stinger or magnet, keep it within ±10° of vertical for vertical readings, avoid loose covers such as motor fan covers, and wait 2–3 seconds for the reading to settle.

What warranty does the IRD301 carry?

1 year.

Can IRD calibrate my IRD301?

Yes. We calibrate the IRD301 together with its IRD521 sensor at our works in Thane and issue a nationally traceable calibration certificate valid for 1 year.

More help: IRD301 Help Center & user manual

Why we built the IRD301

Launched on 24 February 2024 – the day IRD Mechanalysis Limited marked 62 years of its incorporation – the IRD301 is built on our many years of experience in routine and preventive maintenance. We designed it to be:

  • Low in cost – so it is easy to procure in bulk
  • Rugged – so it lasts for years of trouble-free operation
  • Easy to use – so less-trained and new personnel can take readings for routine and preventive maintenance

Equipping a whole plant or team?

Ask us for a bulk price on IRD301 kits.

Request a Bulk / Plant-wide QuoteWhatsApp Us
Items have been added to cart.
One or more items could not be added to cart due to certain restrictions.
Close
Added to cart
- There was an error adding to cart. Please try again.
Quantity updated
- An error occurred. Please try again later.
Deleted from cart
- Can't delete this product from the cart at the moment. Please try again later.